Electrostatic Discharge
Esco Home | Contact Us


FTR-1 Foot Tester

Features
- Test range of 0.9 ~ 35 mega Ohms
- Dual footwear station for repeatable checks on both right and left feet at the same time
- Audible and visual indication of system status
- Light indicator ( red, green, yellow)
- Sturdy plastic coated metal frame with wall mounting bracket as standard

Calibration
Calibration is recommended on average of every twelve months. A resistance decade box can be used. Connect on of the two left stainless steel foot print. Set the resistance just below the lowest acceptable resistance level of the tester. The RED low fail LED will light and an audible buzzer will pulse on the left side of the tester, when you push the "Press to Test" button. Increase the resistance of your right foot, connect the decade box lead currently making contact with the left stainless steel foot print, over to the right foor print and repeat the process.

Part Number : SCJ/EQ-FTR-1

Power Supply
9V battery
Test Voltage
Nominal 9V
Temperature Range
Operating
Storage
5-59°C
(-15 to 60°C)
Relative Humidity
0% - 90% (non-condensing)
Accuracy
+/- 5%
Repeatability
+/- 5%
Weight
4.5 kg
Dimensions

190 x 135 x 45mm

Height of station
1m - 39 1/2"
Light Indicator
HIGH FAIL
PASS
LOW FAIL
LOW BATTERY
RED - System resistance in excess 35 megaOhm
GREEN - acceptable resistance
RED- System resistance less than 0.9 megaOhms
YELLOW

the Esco Group of Companies © 2003